Final report on key comparison CCQM-K59: Determination of nitrite and nitrate in calibration solutions

Michal Máriássy1, Akiharu Hioki2, Leonid A Konopelko3, Irina Dimchoglo3, Michael Winchester4, Therese Butler4, Ryan Case4, Ana Hernández5, Ariel Galli5, Pablo Alvarez5, Joung Hae Lee6, Chantal Royer7, Naijie Shi8, Jingbo Chao8, Bing Wu8 and Haifeng Li8

Show affiliations


KEY COMPARISON

In this key comparison anion calibration solutions of nitrate and nitrite were investigated. The mass fractions of the anions in both solutions were about 1 g/kg. For the nitrate comparison 8 participants provided results; 3 analytical techniques were used: ion chromatography, capillary electrophoresis and coulometry after ion exchange. The nitrite amount content was determined by 7 participants using one of the following 3 techniques: ion chromatography, titrimetry and capillary electrophoresis.

The following institutes participated in this key comparison: INTI (Argentina), KRISS (Korea), LNE (France), NIM (Pepole's Republic of China), NIST (USA), NMIJ (Japan), SMU (Slovakia) and VNIIM (Russia).

The variability (RSD) of the results is about 0.75% for both the nitrite and the nitrate solutions. Compared to the key comparison CCQM-K29 the results of CCQM-K59 were significantly worse. This is in part due to the measurement methods used, possibly also due to the standards used by the institutes.

A pilot study (P89) was performed in parallel on the same calibration solutions used in this K59 comparison study by laboratories preferring to participate in the pilot study and on a seawater sample containing about 0.1 mg/kg nitrite and 1 mg/kg nitrate. The results of the pilot study are reported separately.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2008)



  1. Final report on key comparison CCQM-K59: Determination of nitrite and nitrate in calibration solutions

    Michal Máriássy et al 2008 Metrologia 45 08015

  2. Quantum field theory on a growing lattice

    Brendan Z. Foster and Ted Jacobson JHEP08(2004)024

  3. Evidence for graphene growth by C cluster attachment

    Elena Loginova et al 2008 New J. Phys. 10 093026

  4. Nonuniqueness of stationary accretion in the Shakura model

    Edward Malec and Krzysztof Roszkowski 2007 J. Phys.: Conf. Ser. 66 012062

  5. Retrieval of interatomic separations of molecules from laser-induced high-order harmonic spectra

    Van-Hoang Le et al 2008 J. Phys. B: At. Mol. Opt. Phys. 41 085603

  6. Activity measurements of the radionuclide 111In for the PTB, Germany in the ongoing comparison BIPM.RI(II)-K1.In-111

    G Ratel et al 2006 Metrologia 43 06002

  7. Comparison of the standards for absorbed dose to water of the PTB, Germany and the BIPM for 60Co γ rays

    C Kessler et al 2006 Metrologia 43 06005

  8. Stochastic quantization of scalar fields in de Sitter spacetime

    T C de Aguiar et al 2009 Class. Quantum Grav. 26 075003

  9. Spontaneous creation of inflationary universes and the cosmic landscape

    Hassan Firouzjahi et al JHEP09(2004)060

  10. Proper time flow equation for gravity

    Alfio Bonanno and Martin Reuter JHEP02(2005)035

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.