CCQM-K32 key comparison and P84 pilot study: Amount of silicon oxide as a thickness of SiO2 on Si

M P Seah

Show affiliations


KEY COMPARISON

CCQM-K32 and P84 were conducted following the pilot study P-38 to demonstrate and document the capability of interested National Metrology Institutes to measure the amount of silicon oxide on silicon wafers expressed as a thickness of SiO2 for nominal thicknesses in the range 1.5 nm to 8 nm. 'Amount of substance' may be expressed in many ways and here the measurand is the thickness of the silicon oxide layer on each of a total of 9 samples of nominal thicknesses in the range 1.5 to 8 nm on (100) and (111) Si substrates, expressed as the thickness of SiO2. This report presents the results from K32 and P84. It includes the data received for the measured values and their associated uncertainties, at 95% confidence, for the 9 samples prior to the deadline for receipt of data. The materials are grown by thermal oxidation in very clean furnaces designed for high quality gate oxides on Si wafers in European and US facilities at the same time as those for the pilot study, P-38. Separate samples were provided to each institute in special containers limiting the carbonaceous contamination to below about 0.3 nm. The 9 samples included 5 samples of ultra-thin SiO2 on (100) orientated wafers of Si and 4 samples of ultra-thin SiO2 on (111) orientated wafers of Si.

The measurements from the 11 participating laboratories were conducted using ellipsometry, neutron reflectivity (NR), x-ray photoelectron spectroscopy (XPS) or x-ray reflectivity measurements (XRR), guided by the protocol developed in the pilot study P-38 and reproduced in the Appendix. The measurements are given in tables 2 and 3. A very small correction is then made for the different samples that each laboratory received as in table 4. Where appropriate, method offset values deduced from the pilot study P-38 are given in table 5 leading to comparative data in tables 6 and 7. Values for the key comparison reference values (KCRVs) and their associated uncertainties are made from the weighted means and the expanded weighted standard deviations of the means from table 6. This is provided in table 8. Graphical plots of equivalence from tables 6 and 8 are provided in figure 1 and equivalence statements are presented in Annex A. Additional XPS and XRR data from NMIJ for K32 were withdrawn from the KCRV evaluation and are given in Annex B.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2008)



  1. CCQM-K32 key comparison and P84 pilot study: Amount of silicon oxide as a thickness of SiO2 on Si

    M P Seah 2008 Metrologia 45 08013

  2. Constraints on supersymmetric grand unified theories from cosmology

    Jonathan Rocher and Mairi Sakellariadou JCAP03(2005)004

  3. Inhomogeneous coupling in two-channel asymmetric simple exclusion processes

    K Tsekouras and A B Kolomeisky 2008 J. Phys. A: Math. Theor. 41 095002

  4. Final Report on CCT-K7: Key comparison of water triple point cells

    M Stock et al 2006 Metrologia 43 03001

  5. Spinors on manifolds with boundary: APS index theorems with torsion

    Kasper Peeters and Andrew Waldron JHEP02(1999)024

  6. Effect of Quantum Point Contact Measurement on Electron Spin State in Quantum Dots

    Zhu Fei-Yun et al 2009 Chinese Phys. Lett. 26 050301

  7. Constrained simulations of the magnetic field in the local Universe and the propagation of ultrahigh energy cosmic rays

    Klaus Dolag et al JCAP01(2005)009

  8. Target mass corrections

    Ingo Schienbein et al 2008 J. Phys. G: Nucl. Part. Phys. 35 053101

  9. Final report of the on-going key comparison BIPM.QM-K1: Ozone at ambient level, comparison with NIST, 2007

    Joële Viallon et al 2008 Metrologia 45 08008

  10. Imaging moving targets from scattered waves

    Margaret Cheney and Brett Borden 2008 Inverse Problems 24 035005

View by subject




Export







Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.