A comparison in the hydraulic pressure range between 10 MPa and 100 MPa was undertaken as EUROMET Project 389. The comparison was originally between five national metrology laboratories but was subsequently expanded to include a further ten participants. The pilot laboratory was the National Physical Laboratory. This report presents the results obtained by each laboratory for the effective area of the piston–cylinder assembly used in the comparison. The results of all participants were found to be consistent with each other and with the calculated reference value, within their claimed uncertainties, at all pressures. The results are therefore considered to be very satisfactory.

Main text. To reach the main text of this Paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).