Quick search Find article
Quick search
Find article

COOMET.M.V-K1 key intercomparison of liquid viscosity measurements

N G Domostroeva and A G Chunovkina

Show affiliations


KEY COMPARISON

This article describes the results of the first COOMET key comparison in which four national metrology institutes (NMIs) took part. Three samples of Newtonian liquids with nominal kinematic viscosities of 30 mm2/s, 100 mm2/s and 1000 mm2/s at 20 °C were used to determine the degrees of equivalence of the national standards of Belarus, Ukraine and Bulgaria to the standards of NMIs that took part in the KC CIPM (CCM.V-K1).

The results of the evaluation of data obtained for all liquids used in the comparison were compared with the reference values (KCRV), obtained in the first key comparison CIPM (CCM.V-K1).

Main text. To reach the main text of this Paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2008)



  1. COOMET.M.V-K1 key intercomparison of liquid viscosity measurements

    N G Domostroeva and A G Chunovkina 2008 Metrologia 45 07009

  2. BIPM comparison BIPM.RI(II)-K1.Np-237 of activity measurements of the radionuclide 237Np and links for the 1998 regional comparison EUROMET.RI(II)-K2.Np-237

    G Ratel et al 2007 Metrologia 44 06002

  3. Activity measurements of the radionuclide 54Mn for the LNE–LNHB, France, NPL, United Kingdom and the MKEH, Hungary, in the ongoing comparison BIPM.RI(II)-K1.Mn-54

    G Ratel et al 2008 Metrologia 45 06009

  4. Final report on intercomparison measurements in the field of gas flow and volume, which are realized at two levels: the second level (B*)

    Stefan Makovnik 2008 Metrologia 45 07018

  5. Final report of the on-going key comparison BIPM.QM-K1: Ozone at ambient level, comparison with NIST, 2007

    Joële Viallon et al 2008 Metrologia 45 08008

  6. Modeling and characterization of electrostatic comb-drive actuators in conducting liquid media

    Vikram Mukundan et al 2009 J. Micromech. Microeng. 19 065008

  7. Comparison of the standards for absorbed dose to water of the PTB, Germany and the BIPM for 60Co γ rays

    C Kessler et al 2006 Metrologia 43 06005

  8. SIM international comparison of 50/60 Hz energy (2002–2007)

    Tom Nelson et al 2008 Metrologia 45 01009

  9. Final report on the bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the NIST (USA) and the BIPM

    R Goebel et al 2008 Metrologia 45 01001

  10. CCQM-P13 pilot study. Metals in artificial food digest

    C S J Wolff Briche 2003 Metrologia 40 08010

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.