R Goebel et al 2008 Metrologia 45 01001 doi:10.1088/0026-1394/45/1A/01001
R Goebel1, R Elmquist2, N Fletcher1 and M Stock1
Show affiliationsThis report describes the results obtained from a NIST–BIPM bilateral comparison of 1 Ω resistance standards in 2007. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.a. Three BIPM 1 Ω travelling standards of CSIRO type were calibrated first at the BIPM, then at the NIST and again at the BIPM after their return. The stability of the transfer standard was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The NIST and the BIPM calibrations were found to be in good agreement, with a mean difference smaller than one standard uncertainty of the comparison.
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Issue 1A ( 1 January 2008)
R Goebel et al 2008 Metrologia 45 01001
C S J Wolff Briche 2003 Metrologia 40 08010
Maritoni Litorja et al 2007 Metrologia 44 02002
M Perkin 2008 Metrologia 45 07006
Rob M Wessel et al 2008 Metrologia 45 08011
R Goebel et al 2008 Metrologia 45 01010
Stefan Makovnik 2008 Metrologia 45 07017
G Ratel et al 2008 Metrologia 45 06006