Quick search Find article
Quick search
Find article

Constraints on a synthetic-noise source for Johnson noise thermometry

FEATURED ARTICLE

D R White1 and S P Benz

Show affiliations


[1]
Brixy H 1971 Temperature measurement in nuclear reactors by noise thermometry Nucl. Instrum. Methods 97 75-80
CrossRef 
[2]
Brixy H, Hecker R, Oehmen J, Rittinghaus K F, Setiawan W and Zimmermann E 1982 Noise thermometry for industrial and metrological applications at KFA Jülich Temperature: its Measurement and Control in Science and Industry vol 6 ed J F Schooley (New York: American Institute of Physics) pp 129-31

[3]
Fink H J 1959 A new absolute noise thermometer at low temperatures Can. J. Phys. 37 1397-406
CrossRef 
[4]
White D R et al 1996 The status of Johnson noise thermometry Metrologia 33 325-35
IOPscience 
[5]
Willink R and White D R 1998 Detection of corruption in Gaussian processes with application to noise thermometry Metrologia 35 787-98
IOPscience 
[6]
Benz S P, Dresselhaus P D and Martinis J 2003 An ac Josephson source for Johnson noise thermometry IEEE Trans. Instrum. Meas. IM-52 545-9
CrossRef 
[7]
Nam S, Benz S, Dresselhaus P D, Tew W L, White D R and Martinis J 2003 Johnson noise thermometry measurements using a quantized voltage noise source for calibration IEEE Trans. Instrum. Meas. IM-52 550-4
CrossRef 
[8]
Nam S W, Benz S P, Martinis J M, Dresselhaus P D, Tew W L and White D R 2003 A ratiometric method for Johnson noise thermometry using a quantized voltage noise source Temperature: its Measurement and Control in Science and Industry vol 7 ed D C Ripple (New York: American Institute of Physics) pp 37-42

[9]
Benz S P, Martinis J M, Nam S W, Tew W L and White D R 2002 A new approach to Johnson noise thermometry using a Josephson quantized voltage source for calibration Proc. TEMPMEKO 2001 ed B Fellmuth et al (Berlin: VDE Verlag) pp 37-44

[10]
Nam S, Benz S, Dresselhaus P, Burroughs C, Tew W L, White D R and Martinis J M 2005 Progress on Johnson noise thermometry using a quantum voltage noise source for calibration IEEE Trans. Instrum. Meas. IM-54 653-7
CrossRef 
[11]
Labenski J R, Tew W L, Nam S W, Benz S P, Dresselhaus P D and Burroughs C J 2007 Resistance-based scaling of noise temperatures from 1 kHz to 1 MHz IEEE Trans. Instrum. Meas. IM-56 481-5
CrossRef 
[12]
Tew W L, Labenski J R, Nam S W, Benz S P, Dresselhaus P D and Burroughs C J 2007 Johnson noise thermometry near the zinc freezing point using resistance-based scaling Int. J. Thermophys. 28 629-45
CrossRef 
[13]
Klein H-H, Klempt G and Storm L 1979 Measurement of the thermodynamic temperature of 4He at various vapour pressures by a noise thermometer Metrologia 15 143-54
IOPscience 
[14]
Höwener H 1986 Noise thermometry in nuclear power plants. A contribution to signal transmission of broad band spectra in noise thermometry, Kernforschungsanlage Jülich GmbH, Institut für Reaktorentwicklung

[15]
White D R and Zimmermann E 2000 Preamplifier limitations on the accuracy of Johnson noise thermometers Metrologia 37 11-23
IOPscience 
[16]
Recommendation 1 (CI 2005): Preparative steps towards new definitions of the kilogram, the ampere, the kelvin and the mole in terms of fundamental constants CIPM, Sèvres, 2005

[17]
White D R and Pickup C P 1987 Systematic errors in digital cross-correlators due to quantisation and differential nonlinearity IEEE Trans. Instrum. Meas. IM-36 47-53

[18]
White D R 1992 Calibration of a digital cross-correlator for Johnson noise thermometry Metrologia 29 23-35
IOPscience 
[19]
White D R and Mason R S 2004 An emi test for Johnson noise thermometry Proc. TEMPMEKO 2004 (Faculty of Mechanical Engineering and Naval Architecture, Zagreb) ed D Zvizdic et al pp 485-90

[20]
Pickup C P 1975 A high-resolution noise thermometer for the temperature range 90-100 K Metrologia 11 151-9
IOPscience 
[21]
White D R, Mason R S and Saunders P 2001 Progress towards a determination of the indium freezing point by Johnson noise thermometry Proc. Tempmeko 2001 ed B Fellmuth et al (Berlin: VDE Verlag) pp 129-34

[22]
Candy J C 1997 An overview of basic concepts Delta-Sigma Data Converters: Theory, Design, and Simulation ed S R Norsworthy et al (Piscataway, NJ: IEEE)

[23]
Benz S P and Hamilton C A 1996 A pulse-driven programmable Josephson voltage standard Appl. Phys. Lett. 68 3171-3
CrossRef 
[24]
Storm L 1986 Precision measurements of the Boltzmann constant Metrologia 22 229-34
IOPscience 
[25]
Middleton D 1996 An Introduction to Statistical Communication Theory (Pisactaway, NJ: IEEE)

crossref member

Related review articles

What's this?
View review articles related to this research to gain an insight into the key trends in this subject area. Related review articles are selected based on PACS/MSC codes, and are no more than three years old.

  1. High-temperature bulk acoustic wave sensors

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.