Quick search Find article
Quick search
Find article

Final report on CCQM-P48: Uranium isotope ratio measurements in simulated biological/environmental materials

C R Quétel, N Lévêque, W De Bolle and E Ponzevera

Show affiliations


PILOT STUDY

CCQM-P48 was a Pilot Study of the Inorganic Analysis Working Group of the Comité Consultatif pour la Quantité de Matière (CCQM) and was organized by the Institute for Reference Materials and Measurements (IRMM) of the European Commission. It was the first CCQM comparison dedicated to isotope ratio measurements.

It involved a rather rare combination of 5 national metrology institutes (NMIs), representing at the Comité International des Poids et Mesures (CIPM) 3 Member States of the Metre Convention and 2 international organisations, and 10 invited laboratories (5 'nuclear experts', 5 'geochemistry/mass spectrometry experts') selected outside CIPM. The aim was to compare capabilities to measure the n(234U)/n(238U), n(235U)/n(238U) and n(236U)/n(238U) ratios in 4 simulated biological/environmental materials prepared at a nominal uranium mass fraction of 5 µg g-1 (series A) and, optionally, in 4 simulated biological/environmental materials prepared at a nominal uranium mass fraction of 5 ng g-1 (series B). In addition, a diluted solution of IRMM-184, a natural uranium isotopic certified reference material (ICRM), had also been distributed for rehearsal as well as for calibration purposes. Participants, however, were free to apply the measurement strategy of their choice.

The test material can be assimilated to a biological/environmental type of sample as the matrix simulated approximately the composition of urine, from the combination in ~ 3% HNO3 solution of purified inorganic salt (aquarium seawater salts to 18 ± 2 g kg-1) and urea (to 17 ± 2 g kg-1). Four uranium isotopic mixtures were produced by mixing uranium ICRMs in the gas phase as UF6. Fractions of these mixtures, following their transformation under the form of solid UO3, were dissolved individually into ~ 3% HNO3 to get separate ~ 1000 mg uranium kg-1 mother solutions. Both series of test materials derived from these solutions (simple dilution into batches of simulated urine), but participants were not informed about this similitude.

The absolute value of the n(235U)/n(238U) ratio in each isotopic mixture was established at the earliest stage (i.e. in the gas phase) by calibrated gas source mass spectrometry measurements, and thus could serve as independent reference value (expanded, k = 2, uncertainty U = 0.05%, relative) for results from series A. 'Mixture mode' (MM) median data based on participants' results were proposed as consensus reference values for all the other sets of results produced.

For samples from series A, 6 laboratories implemented a combination of sample digestion and matrix separation steps, whereas 3 laboratories did not report any particular sample treatment (apart possibly from dilution). Only mass spectrometry was employed for isotope ratio measurements, including 9 MC-ICPMS, 3 HR-ICPMS, 2 TIMS and 1 ICP-QMS. For n(235U)/n(238U) ratios, results from 11 laboratories were in agreement within stated U with reference values for at least 3 mixtures; stated relative U were always > 0.0120% (except for 1 participant) and always ≤ 0.7% (except for 1 participant with U > 1% for 3 samples). Results on n(234U)/n(238U) ratios were almost always within ± 3% around the calculated MM median value. For the n(236U)/n(238U) smallest ratio, ~ 5 × 10-7, results relative to the calculated MM median value were within ± 20% for 8 participants, between 20% and 50% above for 3 other participants, over 50% above for 1 participant, and 3 participants did not report results. The perception of which factor caused the largest contribution to these uncertainty estimations differed among participants because of differences in the analytical methodologies deployed but mostly because of wide differences in concepts of uncertainty estimation.

Main text. To reach the main text of this paper, click on Final Report.

The final report has been peer-reviewed and approved for publication by the CCQM IAWG.


Dates

Issue 1A ( 1 January 2007)



  1. Final report on CCQM-P48: Uranium isotope ratio measurements in simulated biological/environmental materials

    C R Quétel et al 2007 Metrologia 44 08010

  2. The Bethe ansatz for Bbb ZS orbifolds of Script N = 4 super Yang-Mills theory

    Niklas Beisert and Radu Roiban JHEP11(2005)037

  3. DC-readout of a signal-recycled gravitational wave detector

    S Hild et al 2009 Class. Quantum Grav. 26 055012

  4. SU(1,1) symmetry of multimode squeezed states

    Z Shaterzadeh-Yazdi et al 2008 J. Phys. A: Math. Theor. 41 055309

  5. Deconstructing noncommutativity with a giant fuzzy moose

    Allan Adams and Michal Fabinger JHEP04(2002)006

  6. Worldline approach to vector and antisymmetric tensor fields

    Fiorenzo Bastianelli et al JHEP04(2005)010

  7. MADNESS applied to density functional theory in chemistry and nuclear physics

    G I Fann et al 2007 J. Phys.: Conf. Ser. 78 012018

  8. Results from the CI-2004 campaign at the BIPM of the BIPM.L-K11 ongoing key comparison

    L Robertsson et al 2005 Metrologia 42 04002

  9. Perturbative calculation of two-photon double electron ionization of helium

    I A Ivanov and A S Kheifets 2008 J. Phys. B: At. Mol. Opt. Phys. 41 095002

  10. Phase transitions and computational difficulty in random constraint satisfaction problems

    F Krząkała and L Zdeborová 2008 J. Phys.: Conf. Ser. 95 012012

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.