Quick search Find article
Quick search
Find article

Update of the BIPM comparison BIPM.RI(II)-K1.Am-241 of activity measurements of the radionuclide 241Am to include the 2006 VNIIM result, links for the 2003 international comparison CCRI(II)-K2.Am-241 and links for the 2006 regional comparison COOMET.RI(II)-K2.Am-241

G Ratel1, C Michotte1, L Johansson2, S Judge2 and I A Kharitonov3

Show affiliations


KEY COMPARISON

Since 1977, seven national metrology institutes (NMIs) have submitted eleven samples of known activity of 241Am to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The activities ranged from about 1.9 MBq to 17 MBq. The results of the CCRI(II)-K2.Am-241 comparison held in 2003 with twenty-one participants have been linked to the BIPM.RI(II)-K1.Am-241 results using the submission to the SIR by the NPL of two ampoules of the mother solution of the CCRI(II) comparison. This has enabled four NMIs to update their earlier SIR results and fifteen NMIs, the IRMM and the BIPM to have their result published, the previous international comparison of 241Am having been held over 40 years ago. The results of a COOMET.RI(II)-K2.Am-241 comparison held in 2006 have also been linked to the SIR results. This is possible through the submission to the SIR of an ampoule of the comparison by the pilot laboratory, the VNIIM. This has enabled two further NMIs to have degrees of equivalence for activity measurements for this radionuclide. The key comparison reference value (KCRV) has been updated to include the recent NPL and VNIIM results. The degree of equivalence between each equivalent activity measured in the SIR, or linked to the SIR, and the KCRV has been calculated and the results are given in the form of a matrix. A graphical presentation is also given. Degrees of equivalence between pairs of participants are similarly given as a matrix.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCRI(II), according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2007)



  1. Update of the BIPM comparison BIPM.RI(II)-K1.Am-241 of activity measurements of the radionuclide 241Am to include the 2006 VNIIM result, links for the 2003 international comparison CCRI(II)-K2.Am-241 and links for the 2006 regional comparison COOMET.RI(II)-K2.Am-241

    G Ratel et al 2007 Metrologia 44 06007

  2. Probabilistic lithium beam data analysis

    R Fischer et al 2008 Plasma Phys. Control. Fusion 50 085009

  3. Can dark matter be a Bose–Einstein condensate?

    C G Böhmer and T Harko JCAP06(2007)025

  4. Microscopic description of black rings in AdS/CFT

    Iosif Bena and Per Kraus JHEP12(2004)070

  5. On the spectrum of the Laplace operator of metric graphs attached at a vertex—spectral determinant approach

    Christophe Texier 2008 J. Phys. A: Math. Theor. 41 085207

  6. Results of the IFIN-HH (Romania), KRISS (Republic of Korea), CMI (Czech Republic) and the BEV (Austria) in the BIPM comparison BIPM.RI(II)-K1.I-131 of activity measurements of the radionuclide 131I

    G Ratel et al 2008 Metrologia 45 06007

  7. Out-of-equilibrium electromagnetic radiation

    Julien Serreau JHEP05(2004)078

  8. Activity measurements of the radionuclide 54Mn for the LNE–LNHB, France, NPL, United Kingdom and the MKEH, Hungary, in the ongoing comparison BIPM.RI(II)-K1.Mn-54

    G Ratel et al 2008 Metrologia 45 06009

  9. EUROMET.M.D-K4/EUROMET Project 702: Comparison of the calibrations of high-resolution hydrometers for liquid density determinations

    S Lorefice et al 2008 Metrologia 45 07008

  10. Molecular electronics in junctions with energy disorder

    Franz J Kaiser et al 2008 New J. Phys. 10 065013

Users also read

What's this?
This innovative new feature generates a list of articles 'also read' by other users based on them reading the original article. Article abstracts citations and references are all considered and weighted accordingly. We hope that this will help you find relevant papers for your research.

  1. Measurement of the activity concentration of the radionuclide Am-241 in a solution
  2. BIPM comparison BIPM.RI(II)-K1.Am-241 of the activity measurements of the radionuclide 241Am

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.