Summary of the BIPM.RI(I)-K1 comparison for air kerma in 60Co gamma radiation

P J Allisy-Roberts, D T Burns and C Kessler

Show affiliations


KEY COMPARISON

International comparisons of air kerma have been made at the Bureau International des Poids et Mesures (BIPM) since 1975. Twenty-one national metrology institutes have taken part, some of which have repeated the comparison over the years. The key comparison reference value (KCRV) is unity, each comparison result being the ratio of the national metrology institute (NMI) evaluation to that of the BIPM standard. The degrees of equivalence between each NMI and the KCRV, and between each pair of NMIs, are given in the form of a matrix, using the most recent published result of the past ten years for each of fifteen NMIs. A graphical presentation is also given.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2007)



  1. Summary of the BIPM.RI(I)-K1 comparison for air kerma in 60Co gamma radiation

    P J Allisy-Roberts et al 2007 Metrologia 44 06006

  2. Final report of EUROMET.T-S1 (EUROMET project 658): The examination of base parameters for ITS-90 scale realisation in radiation thermometry

    H C McEvoy 2008 Metrologia 45 03002

  3. Update of the BIPM.RI(II)-K1.Rn-222 comparison of activity measurements for the radionuclide 222Rn to include the PTB

    G Ratel et al 2006 Metrologia 43 06006

  4. Final report on the CIPM key comparison CCPR-K1.b: Spectral irradiance 200 nm to 350 nm

    Peter Sperfeld 2008 Metrologia 45 02002

  5. Comparison of the standards for air kerma of the ITN (Portugal) and the BIPM for 60Co γ-rays

    P J Allisy-Roberts et al 2009 Metrologia 46 06007

  6. Final report on key comparison CCQM-K42: Determination of chromium, copper, iron, manganese and zinc in aluminium alloy

    Siegfried Noack and Ralf Matschat 2008 Metrologia 45 08012

  7. Activity measurements of a suite of radionuclides (40K, 137Cs, 210Pb, 210Po, 228Ra, 232Th, 234U, 235U, 238U, 238Pu, 239Pu, 239+240Pu, 241Am) in vegetal reference material (seaweed)

    I Outola et al 2008 Metrologia 45 06014

  8. Final Report on CCT-K7: Key comparison of water triple point cells

    M Stock et al 2006 Metrologia 43 03001

  9. Final report on EUROMET.M.P-S4: Bilateral pressure comparison in gas media between LNE (France) and UME (Turkey) (gauge mode) in the range from 0.04 MPa to 1.75 MPa

    Ilknur Kocas et al 2008 Metrologia 45 07005

  10. Final report on the bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NML, Ireland and the BIPM, June–October 2007

    O Power and N Fletcher 2008 Metrologia 45 01002

View by subject