Quick search Find article
Quick search
Find article

BIPM comparison BIPM.RI(II)-K1.Np-237 of activity measurements of the radionuclide 237Np and links for the 1998 regional comparison EUROMET.RI(II)-K2.Np-237

G Ratel1, C Michotte1, H Janßen2, K Kossert2, G Sibbens3, T Altzitzoglou3, S Pommé3, M J Woods4 and S Judge4

Show affiliations


KEY COMPARISON

In 1998, five national metrology institutes (NMI), an international laboratory and the Bureau International des Poids et Mesures (BIPM) took part in a comparison of activity measurements of 237Np as part of the EUROMET project No 416 comparison identifier EUROMET.RI(II)-K2.Np-237. The nominal activity per mass of the 237Np solution distributed was 150 kBq g-1. The three ampoules received by the BIPM for this comparison were also measured in the International Reference System (SIR) for activity comparison at the BIPM (identifier BIPM.RI(II)-K1.Np-237). Two other participants to the EUROMET comparison also submitted ampoules of the same 237Np solution to the SIR. These SIR measurements enable the EUROMET comparison to be linked to the BIPM.RI(II)-K1.Np-237. The degrees of equivalence between each laboratory and the key comparison reference value (KCRV) have been calculated and the results are given in the form of a graph and matrix for the three SIR participants and four other NMIs from the EUROMET comparison.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2007)



  1. BIPM comparison BIPM.RI(II)-K1.Np-237 of activity measurements of the radionuclide 237Np and links for the 1998 regional comparison EUROMET.RI(II)-K2.Np-237

    G Ratel et al 2007 Metrologia 44 06002

  2. Activity measurements of the radionuclide 54Mn for the LNE–LNHB, France, NPL, United Kingdom and the MKEH, Hungary, in the ongoing comparison BIPM.RI(II)-K1.Mn-54

    G Ratel et al 2008 Metrologia 45 06009

  3. Final report on intercomparison measurements in the field of gas flow and volume, which are realized at two levels: the second level (B*)

    Stefan Makovnik 2008 Metrologia 45 07018

  4. Final report of the on-going key comparison BIPM.QM-K1: Ozone at ambient level, comparison with NIST, 2007

    Joële Viallon et al 2008 Metrologia 45 08008

  5. Modeling and characterization of electrostatic comb-drive actuators in conducting liquid media

    Vikram Mukundan et al 2009 J. Micromech. Microeng. 19 065008

  6. Comparison of the standards for absorbed dose to water of the PTB, Germany and the BIPM for 60Co γ rays

    C Kessler et al 2006 Metrologia 43 06005

  7. SIM international comparison of 50/60 Hz energy (2002–2007)

    Tom Nelson et al 2008 Metrologia 45 01009

  8. Final report on the bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the NIST (USA) and the BIPM

    R Goebel et al 2008 Metrologia 45 01001

  9. CCQM-P13 pilot study. Metals in artificial food digest

    C S J Wolff Briche 2003 Metrologia 40 08010

  10. Final report on the CCPR-S2 supplementary comparison of area measurements of apertures for radiometry

    Maritoni Litorja et al 2007 Metrologia 44 02002

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.