A positioning system and photometer as a whole are termed 'goniophotometer', which is defined as a specialized instrument for measuring the angular variation of a given photometric level. This paper explains the design and calibration of a new automated goniophotometer based on double reflection in order to reduce the size of the system. This goniophotometer is suitable for measuring several photometric magnitudes (luminance, luminous intensity...) with no need for auxiliary detectors.


PACS

07.60.Dq Photometers, radiometers, and colorimeters

06.20.fb Standards and calibration

07.85.-m X- and γ-ray instruments

06.30.Ka Basic electromagnetic quantities

Subjects

Instrumentation and measurement

Dates

Issue 3 (June 2006)

Received 26 September 2005

Published 21 February 2006



  1. Double reflection goniophotometer

    V F Muñoz-Martínez et al 2006 Metrologia 43 185

  2. Take your physics lesson outside

    Chris King 2008 Phys. Educ. 43 132

  3. Inclined-plane model of the 2004 Tour de France

    Benjamin Lee Hannas and John Eric Goff 2005 Eur. J. Phys. 26 251

  4. Low-lying dipole modes in vibrational nuclei studied by photon scattering

    Ulrich Kneissl et al 2006 J. Phys. G: Nucl. Part. Phys. 32 R217

  5. An inverse problem for the recovery of active faults from surface observations

    Ioan R Ionescu and Darko Volkov 2006 Inverse Problems 22 2103

  6. Sulfur K-edge XANES spectroscopy as a tool for understanding sulfur chemical state in anaerobic granular sludge

    E van Hullebusch et al 2009 J. Phys.: Conf. Ser. 190 012184

  7. Three-electron matrix elements near the middle of the atomic f shell

    B R Judd and E Lo 1994 J. Phys.: Condens. Matter 6 L799

  8. In-situ investigation of Bi thin film condensation by surface sensitive X-ray absorption spectroscopy at cryogenic temperatures

    D Lützenkirchen-Hecht et al 2009 J. Phys.: Conf. Ser. 190 012114

  9. Electron-impact excitation of B+ using the R-matrix with pseudo-states method

    N R Badnell et al 2003 J. Phys. B: At. Mol. Opt. Phys. 36 1337

  10. Reference tissue quantification of DCE-MRI data without a contrast agent calibration

    Simon Walker-Samuel et al 2007 Phys. Med. Biol. 52 589

Users also read

What's this?
This innovative new feature generates a list of articles 'also read' by other users based on them reading the original article. Article abstracts citations and references are all considered and weighted accordingly. We hope that this will help you find relevant papers for your research.

  1. A new goniophotometer for the calibration of small luminous flux standard lamps