Version: 6.3

Final report on the key comparison CCAUV.A-K3

Author

Vicente Cutanda Henríquez1 and Knud Rasmussen2

Affiliations

1 Centro Nacional de Metrología, Mexico
2 Danish Primary Laboratory for Acoustics, Denmark
3 Present address: University of Vigo, Spain

Journal

Metrologia Create an alert RSS this journal

Issue

Volume 43, Technical Supplement

Citation

Vicente Cutanda Henríquez and Knud Rasmussen 2006 Metrologia 43 09001

doi: 10.1088/0026-1394/43/1A/09001


KEY COMPARISON

 
Tag this article
Abstract

This is the final report for key comparison CCAUV.A-K3 on the sensitivity calibration of laboratory standard microphones in the frequency range from 31.5 Hz to 31.5 kHz. Fifteen national measurement laboratories took part in this key comparison and the Centro Nacional de Metrología (CENAM), Mexico, piloted the project with the assistance of the Danish Primary Laboratory for Acoustics (DPLA), Denmark. Four travelling standard microphones were circulated to the participants in two loops linked through the measurements of the CENAM and the DPLA. The participants' results in the form of sensitivity measurements (dB re 1 V/Pa) and full uncertainty budgets were collected throughout the project. Reference values for all four standard microphones have been calculated using a linear least squares minimization method. The differences between measurements and references have been averaged to obtain the degrees of equivalence per laboratory and interlaboratory. The deviations are all below 0.1 dB, except at 31.5 kHz. A frequency of 1000 Hz has been chosen to illustrate the degrees of equivalence. In all cases, the deviation is smaller than the associated uncertainty.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

Dates

Issue 1A ( 1 January 2006)



  1. Final report on the key comparison CCAUV.A-K3

    Vicente Cutanda Henríquez and Knud Rasmussen 2006 Metrologia 43 09001

  2. Spectroscopic Evidence for a 5.4 Minute Orbital Period in HM Cancri

    Gijs H. A. Roelofs et al 2010 ApJ 711 L138

View by subject


Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.