Quick search Find article
Quick search
Find article

Update of the ongoing comparison BIPM.RI(II)-K1.Co-60 including activity measurements of the radionuclide 60Co for the NMIJ, Japan and the IRMM (Geel)

G Ratel1, C Michotte1, Y Hino2, J Keightley3 and U Wätjen3

Show affiliations


KEY COMPARISON

Since 2004, both the National Metrology Institute of Japan (NMIJ) and the Institute for Reference Materials and Measurements (Geel) have submitted samples of known activity of 60Co to the International Reference System (SIR). The values of the activity submitted were about 1.4 MBq. The key comparison results now include an IRMM result for the first time and have been updated for Japan. The key comparison reference value has been re-evaluated following the recommendations of the CCRI(II) and the matrix of degrees of equivalence in the key comparison database now contains 22 results, identifier BIPM.RI(II)-K1.Co-60.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by Section II of the Consultative Committee for Ionizing Radiation (CCRI(II)), according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2006)



  1. Update of the ongoing comparison BIPM.RI(II)-K1.Co-60 including activity measurements of the radionuclide 60Co for the NMIJ, Japan and the IRMM (Geel)

    G Ratel et al 2006 Metrologia 43 06003

  2. Results from the CII-2006 campaign at the BIPM of the BIPM.L-K11 ongoing key comparison

    Lennart Robertsson et al 2007 Metrologia 44 04003

  3. Final report of the SIM 60Co absorbed-dose-to-water comparison SIM.RI(I)-K4

    C K Ross et al 2008 Metrologia 45 06011

  4. EUROMET EM.M-S1 - EUROMET Project No. 597: Comparison of magnetic flux by means of a coil transfer standard

    J Kupec et al 2003 Metrologia 40 01006

  5. Final report on CCQM-K9.2: Subsequent key comparison on pH determination of phosphate buffer by Harned cell measurements

    Petra Spitzer et al 2008 Metrologia 45 08006

  6. EUROMET Project 852: A comparison between Italian and Swiss gas flow standards in the range 0.3 m3/h to 25 m3/h

    Henri Baumann et al 2008 Metrologia 45 07011

  7. Final report of the APMP comparison of mass standards: APMP.M.M-K6 (SUB) multiples mass key comparison

    Le Hong Phong 2008 Metrologia 45 07016

  8. Bilateral direct comparison of Josephson array voltage standards of the PTB (Germany) and PEL (Croatia): Draft B report for EUROMET.EM-S28

    Ralf Behr et al 2008 Metrologia 45 01011

  9. Final report on key comparison APMP.QM-K1.d: sulphur dioxide in nitrogen

    Kenji Kato et al 2008 Metrologia 45 08010

  10. Three dimensional adaptive mesh refinement on a spherical shell for atmospheric models with lagrangian coordinates

    Joyce E Penner et al 2007 J. Phys.: Conf. Ser. 78 012072

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.