Quick search Find article
Quick search
Find article

Final Report on Key Comparison APMP.M.P-K7 in hydraulic gauge pressure from 10 MPa to 100 MPa

Tokihiko Kobata1, A K Bandyopadhyay2, Ken Moore3, Alaaeldin A E Eltawil4, Sam-Yong Woo5, T K Chan6, Wu Jian7, John Man8, Nguyen Ngoc Con9, Chen Soo Fatt10, Wenda Permana11, Mohamad Aldammad12, Wladimir Sabuga13, Tawat Changpan14, Chen-Chuan Hung15 and Zhang Pengcheng16

Show affiliations


KEY COMPARISON

This report describes the results of a key comparison of hydraulic high-pressure standards at 16 national metrology institutes (NMIs: NMIJ/AIST, NPLI, CSIR-NML, NIS, KRISS, SCL, SPRING, NMIA, VMI, NML-SIRIM, KIM-LIPI, NSCL, PTB, NIMT, CMS/ITRI and NIM) was carried out during the period October 2002 to July 2004 within the framework of the Asia-Pacific Metrology Programme (APMP) in order to determine their degrees of equivalence at pressures in the range 10 MPa to 100 MPa for gauge mode. The pilot institute was the National Metrology Institute of Japan (NMIJ)/AIST. All participating institutes generally used hydraulic pressure balances as their pressure standards. High-precision pressure transducers were used as transfer standards. The sensing element of the transducer was a precision quartz crystal resonator. To ensure the reliability of the transfer standard, two pressure transducers were used on a transfer standard unit. Three nominally identical transfer packages were circulated independently to reduce the time required for the measurements. During this comparison, the three transfer standards were calibrated simultaneously at the pilot institute 11 times in total. From the calibration results, the behaviours of the transfer standards during the comparison period were well characterized and it was presented that the capabilities of the transfer standards to achieve this key comparison were sufficient. The degrees of equivalence of each national measurement standard were expressed quantitatively by two terms, deviations from the key comparison reference values and pair-wise differences of their deviations. The degrees of equivalence in this comparison were also transferred to the corresponding CCM key comparison, CCM.M.P-K7. The hydraulic pressure standards in the range 10 MPa to 100 MPa for gauge mode of the 16 participating NMIs were found to be equivalent within their claimed uncertainties.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2005)



View by subject




Export







Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.