Karl Jousten et al 2005 Metrologia 42 07001 doi:10.1088/0026-1394/42/1A/07001
Karl Jousten1, Mercede Bergoglio2, Anita Calcatelli2, Jean-Noel Durocher3, John Greenwood4, Rifat Kangi5, Jean-Claude Legras3, Carmen Matilla6 and Janez Setina7
Show affiliationsWithin the Euromet region a regional key comparison (Euromet.M.P-K1.b) was carried out in order to compare national vacuum standards in the pressure range from 3 × 10-4 Pa to 0.9 Pa. The participants were the BNM-LNE (France), CEM (Spain), IMGC-CNR (Italy), IMT (Slovenia), NPL (United Kingdom), UME (Turkey), and the PTB (Germany) as pilot laboratory. The measurements were carried out from April 2000 to February 2002.
Two spinning rotor gauges served as transfer standards and showed a good transport stability. The effective accommodation coefficients of the rotors had to be determined at eight target points at and between 3 × 10-4 Pa and 0.9 Pa. The uncertainty of the generated pressure in the calibration standard was reported as part of the calibration report by each laboratory. All additional uncertainties that were related to the transfer standard were evaluated by the pilot laboratory in order to have a uniform uncertainty analysis for all participants and in order to emphasize the importance of the reported uncertainty of the generated pressure.
From the available data a Euromet reference value was calculated at each target pressure. The results from most of the laboratories showed a good agreement with the reference value within the combined uncertainties. A few values of three of the laboratories were significantly off the reference value.
At the highest target pressure of 0.9 Pa a linkage to the lowest target pressure at 1 Pa of the key comparison CCM.P-K4 was possible by means of the results of three laboratories that took part in both comparisons.
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the Mutual Recognition Arrangement (MRA).
Issue 1A ( 1 January 2005)
Karl Jousten et al 2005 Metrologia 42 07001
HERMES collaboration JHEP06(2008)017
D Meiser and M J Holland 2009 New J. Phys. 11 033002
Jai Seong Choi et al 2008 J. Micromech. Microeng. 18 035008
Ofer Aharony et al JHEP07(2003)030
Rong-Gen Cai JCAP02(2004)007
D Charalambidis et al 2008 New J. Phys. 10 025018
GeV at RHIC
Yao Ming (for STAR Collaboration) 2008 J. Phys. G: Nucl. Part. Phys. 35 044071
Marek Kowalski JCAP05(2005)010
Tokihiko Kobata et al 2005 Metrologia 42 07006