Activity measurements of the radionuclide 134Cs for the IRMM, Geel, PTB, Germany, OMH, Hungary, LNE-LNHB, France and the NMIJ, Japan in the ongoing comparison BIPM.RI(II)-K1.Cs-134

G Ratel1, C Michotte1, U Wätjen2, H Janßen3, L Szücs4, N Coursol5 and Y Hino6

Show affiliations


KEY COMPARISON

Since 2004, the Institute for Reference Materials and Measurements (IRMM, Geel, Belgium), Physikalisch-Technische Bundesanstalt (PTB, Germany), Országos Mérésügyi Hivatal (OMH, Hungary), Laboratoire national de métrologie et d'essais–Laboratoire national Henri Becquerel (LNE–LNHB, France) and the National Metrology Institute of Japan (NMIJ) each submitted one sample of known activity of 134Cs to the International Reference System (SIR). The OMH, PTB and LNE–LNHB results replace their 1992, 1994 and 1998 SIR measurements respectively while the IRMM and NMIJ submissions are their first measurements in the SIR, replacing the 1978 CCRI(II) comparison results. The values of the activity submitted were between about 0.6 MBq and 5.4 MBq. The key comparison results have been added to the matrix of degrees of equivalence that now contains 12 results, identifier BIPM.RI(II)-K1.Cs-134, to which the remaining ten eligible results from the CCRI(II)-K2.Cs-134 held in 1978 are linked.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by Section II of the Consultative Committee for Ionizing Radiation (CCRI(II)), according to the provisions of the Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2005)



  1. Activity measurements of the radionuclide 134Cs for the IRMM, Geel, PTB, Germany, OMH, Hungary, LNE-LNHB, France and the NMIJ, Japan in the ongoing comparison BIPM.RI(II)-K1.Cs-134

    G Ratel et al 2005 Metrologia 42 06013

  2. Report on a comparison of pressure standards in the range 10 MPa to 100 MPa

    M Perkin 2008 Metrologia 45 07013

  3. Update of the BIPM comparison BIPM.RI(II)-K1.Ba-133 of activity measurements of the radionuclide 133Ba to include the results of the IFIN-HH (Romania) and the NMIJ (Japan)

    G Ratel et al 2008 Metrologia 45 06002

  4. Comparison of the NIST and NRC Josephson voltage standards (SIM.EM.BIPM-K10.b)

    Yi-hua Tang and Barry Wood 2008 Metrologia 45 01005

  5. Final report on CCM key comparison CCM.P-K2: Pressure (10 kPa to 120 kPa) absolute mode

    Michael Perkin et al 2008 Metrologia 45 07002

  6. Update of the BIPM comparison BIPM.RI(II)-K1.Ho-166m activity measurements to include the IRA and the NPL and a re-evaluation of the degrees of equivalence for the APMP.RI(II)-K2.Ho-166m comparison

    C Michotte et al 2009 Metrologia 46 06008

  7. EUROMET project no 429: Comparison of 10 V electronic voltage standards

    F Liefrink et al 2003 Metrologia 40 01004

  8. Comparison of national air kerma standards for ISO 4037 narrow spectrum series in the range 30 kV to 300 kV

    L Büermann et al 2008 Metrologia 45 06013

  9. Final report on EUROMET supplementary comparison EUROMET.L-S12: Calibration of gauge blocks by mechanical comparison

    Howard McQuoid and Zbigniew Ramotowski 2008 Metrologia 45 04002

  10. Magnons, their solitonic avatars and the Pohlmeyer reduction

    Timothy J. Hollowood and J. Luis Miramontes JHEP04(2009)060

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.