Quick search Find article
Quick search
Find article

Results from the CII-2004 campaign at the BIPM of the BIPM.L-K11 ongoing key comparison

L Robertsson1, M Zucco1, L-S Ma1, Quin Jin2, Xiuying Liu2, Zhongyou Liu2, J-P Wallerand3, Steven Van den Berg4, Reine Johansson5 and Håkan Skoogh5

Show affiliations


KEY COMPARISON

Lasers from four national metrological institutes (NMIs) were brought to the BIPM in November 2004 as part of the BIPM.L-K11 ongoing key comparison initiated by the Comité Consultative des Longueurs (CCL) 11th meeting in 2003. The absolute frequency of the f component of the R(127) 11-5 transition was measured for these lasers following the Protocol for BIPM.L-K11. The results of these measurements are compiled in the present paper. The comparison reports, as communicated by each participant, are included as Appendices.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2005)



  1. Results from the CII-2004 campaign at the BIPM of the BIPM.L-K11 ongoing key comparison

    L Robertsson et al 2005 Metrologia 42 04003

  2. Update of the BIPM comparison BIPM.RI(II)-K1.Cr-51 to include new activity measurements for the LNE–LNHB (France) and the pilot study result of the LNMRI (Brazil)

    G Ratel et al 2009 Metrologia 46 06001

  3. Link between the comparison EUROMET.EM.BIPM-K11.b and the ongoing comparison BIPM.EM-K11.b

    Dominique Reymann 2003 Metrologia 40 01005

  4. Final report on supplementary comparison APMP.M.P-S2 (bilateral comparison) at a nominal pressure of 0.05 Pa

    Pardeep Mohan and Patrick J Abbott 2008 Metrologia 45 07003

  5. Comparison of the standards for absorbed dose to water of the VSL and the BIPM for 60Co γ-rays

    C Kessler et al 2009 Metrologia 46 06009

  6. Final report on subsequent key comparison CCQM-K18.1: pH of carbonate buffer

    L Vyskocil et al 2008 Metrologia 45 08014

  7. APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)

    J H Lee et al 2008 Metrologia 45 06012

  8. Final report on the bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the CMI (Czech Republic) and the BIPM

    R Goebel et al 2008 Metrologia 45 01004

  9. Update of the ongoing comparison BIPM.RI(II)-K1.Ga-67 to include the activity measurements of the LNE–LNHB, France

    G Ratel et al 2006 Metrologia 43 06008

  10. An intercomparison of low flow gas facilities at eleven European laboratories using a Molbloc transfer package: EURAMET.MM.FF-S3 (EURAMET Project no 806)

    C Probert et al 2008 Metrologia 45 07012

Users also read

What's this?
This innovative new feature generates a list of articles 'also read' by other users based on them reading the original article. Article abstracts citations and references are all considered and weighted accordingly. We hope that this will help you find relevant papers for your research.

  1. Results from the CI-2005 campaign at the BIPM of the BIPM.L-K11 ongoing key comparison
  2. Results from the CI-2004 campaign at the BIPM of the BIPM.L-K11 ongoing key comparison

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.