Results from the CI-2004 campaign at the BIPM of the BIPM.L-K11 ongoing key comparison

L Robertsson1, M Zucco1, L-S Ma1, O Terra2, F Saraiva3, S Gentil3, C Chekirda4, Yu Zakharenko4, V Fedorin4 and L Mostert5

Show affiliations


KEY COMPARISON

Lasers from four national metrological institutes (NMIs) were brought to the BIPM in March 2004 as part of the BIPM.L-K11 ongoing key comparison initiated by the Comité Consultative des Longeurs (CCL) 11th meeting in 2003. The absolute frequency of the f component of the R(127) 11-5 transition was measured for these lasers following the Protocol for BIPM.L-K11. The results of these measurements are compiled in the present paper. The comparison reports, as communicated by each participant, are included as Appendices.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the Mutual Recognition Arrangement (MRA).


Dates

Issue 1A ( 1 January 2005)



  1. Results from the CI-2004 campaign at the BIPM of the BIPM.L-K11 ongoing key comparison

    L Robertsson et al 2005 Metrologia 42 04002

  2. International Key Comparison CCQM-K26.b and Pilot Study CCQM-P50.b: Comparison of primary standards of sulphur dioxide (SO2) in synthetic air

    Masaaki Maruyama et al 2007 Metrologia 44 08007

  3. Final report on comparison COOMET.T-K3: Regional comparisons of the national standards of temperature in the range from the triple point of water to the freezing temperature of zinc

    A I Pokhodun and A G Ivanova 2008 Metrologia 45 03005

  4. Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the LNE-LNHB, France and the BIPM in medium-energy x-rays

    D T Burns et al 2008 Metrologia 45 06004

  5. Final report on key comparison COOMET.M.P-K1 in the range 0.05 MPa to 0.5 MPa of pneumatic gauge pressure

    Yu Kiselev et al 2008 Metrologia 45 07015

  6. Final Report on the International Comparison of Luminous Responsivity CCPR-K3.b

    R Köhler et al 2004 Metrologia 41 02001

  7. Final report on the APMP comparison of capacitance at 100 pF (APMP supplementary comparison APMP.EM-S7)

    Leigh Johnson et al 2008 Metrologia 45 01003

  8. Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the NMIJ and the BIPM in low-energy x-rays

    D T Burns et al 2008 Metrologia 45 06015

  9. CCQM-K32 key comparison and P84 pilot study: Amount of silicon oxide as a thickness of SiO2 on Si

    M P Seah 2008 Metrologia 45 08013

  10. Final report on supplementary comparison EUROMET.M.P-S3 of absolute pressure standards in the barometric range from 80 kPa to 110 kPa

    Pierre Otal et al 2008 Metrologia 45 07004

Users also read

What's this?
This innovative new feature generates a list of articles 'also read' by other users based on them reading the original article. Article abstracts citations and references are all considered and weighted accordingly. We hope that this will help you find relevant papers for your research.

  1. The CCL-K11 ongoing key comparison: final report for the year 2010
  2. Results from the CI-2005 campaign at the BIPM of the BIPM.L-K11 ongoing key comparison
  3. Results from the CII-2004 campaign at the BIPM of the BIPM.L-K11 ongoing key comparison

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.