KEY COMPARISON

In the period 1998-2001, EUROMET organized a comparison of measurements of 10 V DC electronic reference standards. This comparison involved 22 national laboratories and the BIPM. The participating laboratories maintain their voltage reference by Josephson effect measurements or via Zener comparisons.

This paper describes the way the EUROMET.EM.BIPM-K11.b reference value xR-EUR is computed in terms of the BIPM.EM-K11.b key comparison reference value xR, i.e. how the quantity (xR-EUR - xR) and its uncertainty are estimated.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the CCEM according to the provisions of the Mutual Recognition Arrangement (MRA).


Dates

Issue 1A (Technical Supplement 2003)



  1. Link between the comparison EUROMET.EM.BIPM-K11.b and the ongoing comparison BIPM.EM-K11.b

    Dominique Reymann 2003 Metrologia 40 01005

  2. Final report on supplementary comparison APMP.M.P-S2 (bilateral comparison) at a nominal pressure of 0.05 Pa

    Pardeep Mohan and Patrick J Abbott 2008 Metrologia 45 07003

  3. Comparison of the standards for absorbed dose to water of the VSL and the BIPM for 60Co γ-rays

    C Kessler et al 2009 Metrologia 46 06009

  4. Final report on subsequent key comparison CCQM-K18.1: pH of carbonate buffer

    L Vyskocil et al 2008 Metrologia 45 08014

  5. APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)

    J H Lee et al 2008 Metrologia 45 06012

  6. Final report on the bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the CMI (Czech Republic) and the BIPM

    R Goebel et al 2008 Metrologia 45 01004

  7. Update of the ongoing comparison BIPM.RI(II)-K1.Ga-67 to include the activity measurements of the LNE–LNHB, France

    G Ratel et al 2006 Metrologia 43 06008

  8. An intercomparison of low flow gas facilities at eleven European laboratories using a Molbloc transfer package: EURAMET.MM.FF-S3 (EURAMET Project no 806)

    C Probert et al 2008 Metrologia 45 07012

  9. Final report of the on-going key comparison BIPM.QM-K1: Ozone at ambient level, comparison with CHMI, 2007

    Joële Viallon et al 2008 Metrologia 45 08005

  10. Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NIM and the BIPM in medium-energy x-rays

    D T Burns et al 2007 Metrologia 44 06008