Quick search Find article
Quick search
Find article

EUROMET project no 429: Comparison of 10 V electronic voltage standards

F Liefrink1, E F Dierikx1, J W Heimeriks1, G Eklund2, I Flouda3, T Funck4, P Helistö5, A Jakab6, J-T Janssen7, B Jeanneret8, H D Jensen9, P O Hetland10, M Lindic11, J-P Lo-Hive12, J Nicolas13, M Nunes14, O Power15, F I Raso Alonso16, D Reymann17, S Selçik18, J Streit19, P Vrabcek20 and W Waldmann21

Show affiliations


KEY COMPARISON

This report presents the results of a comparison of measurements on four electronic DC reference standards performed by national metrology institutes in the EUROMET region and BIPM. The results of the comparison, in terms of degrees of equivalence, show that there is a good agreement between the measurement results of the participants. The results also show that the time-dependent fluctuations in the output voltages of the travelling standards provide one of the main sources of uncertainty.

Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.

The final report has been peer-reviewed and approved for publication by the EUROMET, comparison identifier EUROMET.EM.BIPM-K11, according to the provisions of the Mutual Recognition Arrangement (MRA).


Dates

Issue 1A (Technical Supplement 2003)



  1. EUROMET project no 429: Comparison of 10 V electronic voltage standards

    F Liefrink et al 2003 Metrologia 40 01004

  2. Update of the BIPM comparison BIPM.RI(II)-K1.Am-241 of activity measurements of the radionuclide 241Am to include the 2006 VNIIM result, links for the 2003 international comparison CCRI(II)-K2.Am-241 and links for the 2006 regional comparison COOMET.RI(II)-K2.Am-241

    G Ratel et al 2007 Metrologia 44 06007

  3. Probabilistic lithium beam data analysis

    R Fischer et al 2008 Plasma Phys. Control. Fusion 50 085009

  4. Can dark matter be a Bose–Einstein condensate?

    C G Böhmer and T Harko JCAP06(2007)025

  5. Microscopic description of black rings in AdS/CFT

    Iosif Bena and Per Kraus JHEP12(2004)070

  6. On the spectrum of the Laplace operator of metric graphs attached at a vertex—spectral determinant approach

    Christophe Texier 2008 J. Phys. A: Math. Theor. 41 085207

  7. Results of the IFIN-HH (Romania), KRISS (Republic of Korea), CMI (Czech Republic) and the BEV (Austria) in the BIPM comparison BIPM.RI(II)-K1.I-131 of activity measurements of the radionuclide 131I

    G Ratel et al 2008 Metrologia 45 06007

  8. Out-of-equilibrium electromagnetic radiation

    Julien Serreau JHEP05(2004)078

  9. Activity measurements of the radionuclide 54Mn for the LNE–LNHB, France, NPL, United Kingdom and the MKEH, Hungary, in the ongoing comparison BIPM.RI(II)-K1.Mn-54

    G Ratel et al 2008 Metrologia 45 06009

  10. EUROMET.M.D-K4/EUROMET Project 702: Comparison of the calibrations of high-resolution hydrometers for liquid density determinations

    S Lorefice et al 2008 Metrologia 45 07008

View by subject




Export





Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.