Effect of substrate hardness and film structure on indentation depth criteria for film hardness testing

Ilze Manika and Janis Maniks

Show affiliations


The indentation depth limits for the Vickers microhardness testing of amorphous, polycrystalline, multilayer and single crystal coatings were investigated. The coating/substrate hardness ratio was varied in the range from 0.01 to 20. The critical indentation depth hc, below which the substrate has a negligible effect on the hardness, was estimated from the experimentally obtained hardness versus indentation depth curves. The results show a marked effect of the coating structure on the size of the influence zone beneath the indenter. The indentation depth limits were found to increase in the row of single crystal → polycrystalline → amorphous coatings. The obtained indentation depth criteria are compared with the reference data obtained by using finite element and kinematic calculations.


PACS

68.60.Bs Mechanical and acoustical properties

62.20.Qp Friction, tribology, and hardness

68.55.-a Thin film structure and morphology

68.65.Ac Multilayers

62.25.-g Mechanical properties of nanoscale systems

81.40.Np Fatigue, corrosion fatigue, embrittlement, cracking, fracture, and failure

Subjects

Surfaces, interfaces and thin films

Nanoscale science and low-D systems

Condensed matter: structural, mechanical & thermal

Dates

Issue 7 (7 April 2008)

Received 6 August 2007, in final form 8 November 2007

Published 12 March 2008



  1. Effect of substrate hardness and film structure on indentation depth criteria for film hardness testing

    Ilze Manika and Janis Maniks 2008 J. Phys. D: Appl. Phys. 41 074010

  2. Final report on EUROMET Project 427, EUROMET.EM-S7: Comparison of AC and DC conductivity standards

    Stuart Harmon et al 2009 Metrologia 46 01009

  3. Gauged U(1)R symmetries and Fayet-Iliopoulos terms in 5D orbifold supergravity

    Hiroyuki Abe and Kiwoon Choi JHEP12(2004)069

  4. Fractional branes and wrapped branes

    Duiliu-Emanuel Diaconescu et al JHEP02(1998)013

  5. Report of the spectral irradiance comparison EURAMET.PR-K1.a.1 between MIKES (Finland) and NIMT (Thailand)

    M Ojanen et al 2009 Metrologia 46 02001

  6. CCQM-K11: The determination of glucose in serum

    Michael J Welch et al 2003 Metrologia 40 08003

  7. B → η(') form factors in QCD

    Patricia Ball and Gareth W. Jones JHEP08(2007)025

  8. Report on Key Comparison EUROMET.EM-K8.1 (DC voltage ratio)

    G Marullo Reedtz and R Cerri 2005 Metrologia 42 01003

  9. BIPM comparison BIPM.RI(II)-K1.F-18 of activity measurements of the radionuclide 18F

    G Ratel and C Michotte 2003 Metrologia 40 06005

  10. Numerical analysis of magneto-electrospinning

    L Xu and Y Wu 2008 J. Phys.: Conf. Ser. 96 012208

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.