Quick search Find article
Quick search
Find article

Micromechanical instruments for ferromagnetic measurements

REVIEW ARTICLE

John Moreland

Show affiliations


[1]
Taylor B N (ed) 2001 The International System of Units (SI) NIST Special Publication 330 (Washington, DC: US Government Printing Office)

[2]
Zijlstra H 1987 Experimental Methods in Magnetism vol 2 (Amsterdam: North Holland)

[3]
Lupien C, Ellman B, Grutter P and Taillefer L 2000 Piezoresistive torque magnetometry below 1 K Appl. Phys. Lett. 76 3564-6
CrossRef 
[4]
Willemin M, Rossel C, Brugger J, Despont M H, Rothuizen H, Vettiger P, Hofer J and Keller H 1998 Piezoresistive cantilever designed for torque magnetometry J. Appl. Phys. 83 1163-70
CrossRef 
[5]
Bolle C A, Aksyuk V, Pardo F, Gammel P L, Zeldov E, Bucher E, Boie R, Bishop D J and Nelson D R 1999 Observation of mesoscopic vortex physics using micromechanical oscillators Nature 399 43-6
CrossRef 
[6]
Harris J G E, Awschalom D D, Matsukura F, Ohno H, Maranowski K D and Gossard A C 1999 Integrated micromechanical cantilever magnetometry of Ga2-xMnxAs Appl. Phys. Lett. 75 1140-2
CrossRef 
[7]
Schwarz M P, Grundler D, Meinel I, Heyn Ch and Heitmann D 1999 Micromechanical cantilever magnetometer with an integrated two-dimensional electron system Appl. Phys. Lett. 74 451-3
CrossRef 
[8]
Harris J G E, Awschalom D D, Maranowski K D and Gossard A C 2000 Magnetization and dissipation measurements in the quantum Hall regime using an integrated micromechanical magnetometer J. Appl. Phys. 87 5102-5
CrossRef 
[9]
Judy J W, Yang H, Irazoqui-Pastor P, Yang K, Myung N, Schwartz M and Nobe K 2000 Ferromagnetic micromechanical magnetometers Tech. Dig. Solid-State Sensor and Actuator Workshop (Hilton Head Island, SC, June 4-8)

[10]
Rossel C, Willemin M, Grasser A, Bothuizen H, Meoijer G I and Keller H 1998 Torsion cantilever as magnetic torque sensor Rev. Sci. Instrum. 69 3199-203
CrossRef 
[11]
Heydon G P, Farley A N, Hoon S R, Valera M S and Thomlinson S L 1997 Resonant torque magnetometry: a new in-situ technique for determining the magnetic properties of MFM tips IEEE Trans. Magn. 33 4059-61
CrossRef 
[12]
Biggar R D and Parpia J M 1998 High-Q oscillator torque magnetometer Rev. Sci. Instrum. 69 3558-62
CrossRef 
[13]
Morrillo J, Su Q, Panchapakesan B, Wuttig M and Novotny D 1998 Micromachined silicon torsional resonator for magnetic anisotropy measurement Rev. Sci. Instrum. 69 3908-12
CrossRef 
[14]
Barnett S J 1935 Gyromagnetic and electron inertia effects Rev. Mod. Phys. 7 129-66
CrossRef 
[15]
Peterson L and Ehrenberg A 1985 Highly sensitive Faraday balance for magnetic susceptibility studies of dilute protein solutions Rev. Sci. Instrum. 56 575-80
CrossRef 
[16]
Flanders P J 1988 An alternating-gradient magnetometer J. Appl. Phys. 63 3940-5
CrossRef 
[17]
Foner S 1996 The vibrating sample magnetometer: experiences of a volunteer J. Appl. Phys. 79 4740-5
CrossRef 
[18]
Gibson G A and Schultz S 1991 A high-sensitivity alternating-gradient magnetometer for use in quantifying magnetic force microscopy J. Appl. Phys. 69 5882-90

[19]
Todorovic M and Schultz S 1998 Miniature high-sensitivity quartz tuning fork alternating gradient magnetometry Appl. Phys. Lett. 73 3595-7
CrossRef 
[20]
Aksyuk V, Balakirev F F, Boebinger G S, Gammel P L, Haddon R C and Bishop D J 1998 Micromechanical `Trampoline' magnetometers for use in large pulsed magnetic fields Science 280 720-2
CrossRef  PubMed 
[21]
Binnig G, Quate C F and Gerber Ch 1986 Atomic force microscope Phys. Rev. Lett. 56 930-3
CrossRef  PubMed 
[22]
Martin Y and Wickramasinge H K 1987 Magnetic imaging by force microscopy with 1000 Å resolution Appl. Phys. Lett. 50 1455-7
CrossRef 
[23]
Hug H J, Stiefel B, van Schendel P J A, Moser A, Martin S and Güntherodt H-J 1999 A low temperature ultrahigh vaccum scanning force microscope Rev. Sci Instrum. 70 3625-40
CrossRef 
[24]
Ascoli C, Baschieri P, Frediani C, Lenci L, Martinelli M, Alzetta G, Celli R M and Pardi L 1996 Micromechanical detection of magnetic resonance by angular momentum absorption Appl. Phys. Lett. 69 3920-2
CrossRef 
[25]
Arimondo E 1967 Angular momentum detection in magnetic resonance at low fields Nuovo Cimento B 52 379-90
CrossRef 
[26]
Alzetta G, Arimondo E, Ascoli C and Gozzini A 1967 Paramagnetic resonance detection at low fields with angular momentum detection Nuovo Cimento B 52 392-402
CrossRef 
[27]
Alzetta G, Arimondo E and Ascoli C 1968 Angular momentum detection of many photon transitions Nuovo Cimento B 54 107-15
CrossRef 
[28]
Sidles J A, Garbini J L, Bruland K J, Rugar D, Züger O, Hoen S and Yannoni C S 1996 Magnetic resonance force microscopy Rev. Mod. Phys. 67 249-65
CrossRef 
[29]
Züger O, Hoen S T, Yannoni C S and Rugar D 1996 Three-dimensional imaging with a nuclear magnetic resonance force microscope J. Appl. Phys. 79 1881-4
CrossRef 
[30]
Rugar D, Yannoni C S and Sidles J A 1992 Mechanical detection of magnetic-resonance Nature 360 563-6
CrossRef 
[31]
Zhang Z, Hammel P C and Wigen P E 1996 Observation of ferromagnetic resonance in a microscopic sample using magnetic resonance force microscopy Appl. Phys. Lett. 68 2005-7
CrossRef 
[32]
Moser A and Weller D 1999 Thermal processes and stability of longitudinal magnetic recording media IEEE Trans. Magn. 35 2808-13
CrossRef 
[33]
Johnson K E 1991 Thin-film recording media: challenges for physics and magnetism in the 1990s J. Appl. Phys. 69 4933-7

[34]
Ouchi K 2000 Overview of latest work on perpendicular recording media IEEE Trans. Magn. 36 16-22
CrossRef 
[35]
Fullerton E E et al 2000 Antiferromagnetically coupled magnetic media layers for thermally stable high-density recording Appl. Phys. Lett. 77 3806-8
CrossRef 
[36]
Sun S, Murray Ch, Weller D, Folks L and Moser A Monodisperse FePt nanoparticles and ferromagnetic FePt nanocrystal superlattices Science 287 1989-92
PubMed 
[37]
Puntes V F, Krishnan K M and Alivisatos A P 2001 Colloidal nanocrystal shape and size control: the case of cobalt Science 291 2115-17
CrossRef  PubMed 
[38]
Rettner C T, Best M E and Terris B D 2000 Patterning of granular magnetic media with a focused ion beam to produce single-domain islands at >140 Gbit/in2 IEEE Trans. Magn. 37 1649-51
CrossRef 
[39]
Tehrani S, Chen E, Durlam M, DeHerrera M, Slaughter J M, Shi J and Kerszykowski G 1999 High density submicron magnetoresistive random access memory J. Appl. Phys. 85 5822-7
CrossRef 
[40]
Parkin S S P et al 1999 Exchange-biased magnetic tunnel junctions and application to nonvolatile magnetic random access memory J. Appl. Phys. 85 5828-33
CrossRef 
[41]
Bauer G E W, Schmidt G and Molenkamp L W 2002 Elementary magnetoelectronics IEEE Potentials 21 6-10
CrossRef 
[42]
Jansen R, van 't Erve O M J, Kim S D, Vlutters R, Anil Kumar P S and Lodder J C 2001 The spin-valve transistor: fabrication, characterization, and physics J. Appl. Phys. 89 7431-6
CrossRef 
[43]
Prinz G and Hathaway K 1995 Magnetoelectronics Phys. Today 48 24-5
CrossRef 
[44]
Kools J C S 1996 Exchange biased spin valves for magnetic storage IEEE Trans. Magn. 32 3165-84
CrossRef 
[45]
Rugar D, Mamin H-J and Guethner P 1989 Improved fiber-optic interferometer for atomic force microscopy Appl. Phys. Lett. 55 2588-90
CrossRef 
[46]
Mertz J, Marti O and Mlynek J 1993 Regulation of a microcantilever response for force feedback Appl. Phys. Lett. 62 2344-6
CrossRef 
[47]
Moreland J and Hubbard T J 2002 High Q resonating cantilevers for in situ measurements of ferromagnetic films Proc. 2001 Microelectromechanical Systems Conf. (Berkeley) (Piscataway, NJ: IEEE) pp 36-39

[48]
Heinrich B, Arrott A S, Cochran J F, Urquhart K B, Myrtle K, Celinski Z and Zhong Q M 1989 In-situ techniques for studying epitaxially grown layers and determining their magnetic properties Mat. Res. Soc. Symp. Proc. 151 177-88

[49]
Roark R J and Young W C 1975 Formulas for Stress and Strain (New York: McGraw Hill)

[50]
Landau L D and Lifshitz E M 1970 Theory of Elasticity (New York: Pergamon)

[51]
Löhndorf M, Moreland J, Kabos P and Rizzo N 2000 Microcantilever torque magnetometry of thin magnetic films J. Appl. Phys. 87 5995-7
CrossRef 
[52]
Bruland K J, Garbini J L, Dougherty W M and Sidles J A 1998 Optimal control of ultrasoft cantilevers for force microscopy J. Appl. Phys. 83 3972-7
CrossRef 
[53]
Heinrich B and Cochran J F 1993 Adv. Phys. 42 523
CrossRef 
[55]
Heinrich B and Cochran J F 1993 Ultrathin metallic magnetic films: magnetic anisotropies and exchange interactions Adv. Phys. 42 523-639
CrossRef 
[56]
Kabos P, Patton C E, Dima M O, Church D B, Stamps R L and Camely R E 1994 Brillouin light scattering on Fe/Cr/Fe thin-film sandwiches J. Appl. Phys. 75 3553-63
CrossRef 
[57]
Kabos P 1995 High Frequency Processes in Magnetic Materials ed G Srinivasan and A Slavin (Singapore: World Scientific) chapter 1

[58]
Nash J M, Kabos P, Staudinger R and Patton C E 1998 Phase profiles of microwave magnetic envelope solitons J. Appl. Phys. 84 2689-99
CrossRef 
[59]
Löhndorf M, Moreland J and Kabos P 2000 Ferromagnetic resonance detection with a torsion mode atomic force microscope Appl. Phys. Lett. 76 1176-8
CrossRef 
[60]
Jander A, Moreland J and Kabos P 2002 All dielectric micromachnined calorimeter for high resolution microwave power measurement Technical Digests of the 15th IEEE Int. Conf. Microelectromechanical Systems pp 635-40

[61]
Jander A, Moreland J and Kabos P 2001 Angular momentum and energy transferred through ferromagnetic resonance Appl. Phys. Lett. 78 2348
CrossRef 
[62]
Barnes J R, Stephenson R J, Woodburn C N, O'Shea S J, Welland M E, Rayment T, Gimzewski J K and Gerber Ch 1994 A femtojoule calorimeter using micromechnaical sensors Rev. Sci. Instrum. 65 3793-8
CrossRef 
[63]
Booth J National Institute of Standards and Technology Private communication

[64]
Moreland J, Löhndorf M, Kabos P and McMichael R D 2000 Ferromagnetic resonance spectroscopy with a micromechanical calorimeter sensor Rev. Sci. Instrum. 71 3099-103
CrossRef 
[65]
Stowe T D, Yasumura K, Kenny T W, Botkin D, Wago K and Rugar D 1997 Attonewton force detection using ultrathin silicon cantilevers Appl. Phys. Lett. 71 288-90
CrossRef 
[66]
Lifshitz R and Roukes M L 2000 Thermoelastic damping in micro- and nanomechanical systems Phys. Rev. B 61 5600-9
CrossRef 
[67]
Yasumara K Y, Stowe T D, Chow E M, Pfafman T, Kenny T W, Stipe B C and Rugar D 2000 Quality factors in micron and submicron thick cantilevers J. Microelectromech. Syst. 9 117-25
CrossRef 
[68]
Mamin H J and Rugar D 2001 A sub-attonewton force detection at millikelvin temperatures Appl. Phys. Lett. 79 3358-60
CrossRef 
[69]
Ketchen M et al 1993 Octagonal washer dc SQUIDs and integrated susceptometers fabricated in a planarized sub-μm Nb-AlOx-Nb technology IEEE Trans. Appl. Supercond. 3 1795-9
CrossRef 
crossref member

View by subject




Export








Please login to access our web services, or create an account if you don't yet have one.

You must have cookies enabled in your web browser to be able to login.

Username
Password

Forgotten your password? Get a new one here.